Commissioning =========================== Power LEDs ----------------- * Stimuli: Plug in in USB-C upstream * Expected: LED `+5V UPSTREAM` * Stimuli: Plug in 5V barrel jack * Expected: LED `+5V PROTECTED` Voltage slew rate -------------------- * Rationale: Verify slew rate * Setup: Connect scope on `GND` and `5V PROTECTED` * Stimuli: Plug in 5V barrel jack * Expected linear slew rate from 0 to 5V * 2ms calculated * 200ms measured... Overvoltage protection ---------------------------- * Precondition: 5V barrel jack connected * Setup: Connect scope on `GND` and `5V PROTECTED` * Stimuli: Shorten `GND` and `5V PROTECTED` * Expected: * LED `+5V PROTECTED` goes off * Voltage `+5V PROTECTED` stays on 0V * Stimuly: 5V barrel jack unplug and plug * Expected: * LED `+5V PROTECTED` goes back on again * Voltage `+5V PROTECTED` goes back to 5V